PRODUCT NAME: APC 100 ALL PURPOSE CLEANER
PRODUCT CODE: 10001, 6001
HMIS CODES: H - 1 F - 0 R - 0 P - B
(HEALTH - FIRE - REACTIVITY - PERSONAL PROTECTION)
HMIS RATING: 0=MINIMAL, 1=SLIGHT, 2=MODERATE, 3=SERIOUS, 4=SEVERE
SECTION I - MANUFACTURER IDENTIFICATION
MANUFACTURER'S NAME: WINSOL LABORATORIES, INC.
ADDRESS:
1417 NW 51ST, SEATTLE, WA. 98107
EMERGENCY PHONE: 206/782-5500
DATE PREPARED: 6-01-89 NAME OF PREPARER: WINSOL
LABORATORIES, INC.
REVISED:01-01-03
SECTION II - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION
HAZARDOUS
CAS # OSHA
ACGIH OTHER
VAPOR WEIGHT
COMPONENTS
PEL TLV
PRESS
%
SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS
SARA TITLE III / SECTION 313 SUPPLIER NOTIFICATION
THIS PRODUCT CONTAINS THE FOLLOWING TOXIC CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986 AND OF 40 CFR 372:
CAS: # CHEMICAL
NAME
PERCENT BY WEIGHT
NONE
BOILING POINT: 212of
SPECIFIC GRAVITY (H2O=1):1.01
VAPOR DENSITY: N.A.
EVAPORATION RATE:<1
V.O.C.: .8%
(ETHER=1)
SOLUBILITY IN WATER<100%
APPEARANCE AND ODOR: AMBER, MILD
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
APC 100 ALL PURPOSE CLEANER IS CONSIDERED NON-FLAMMABLE
FLASH POINT: N.A.
FLAMMABLE LIMITS IN AIR BY VOLUME- LOWER: NA
UPPER:NA
EXTINGUISHING MEDIA: WATER
SPECIAL FIRE FIGHTING PROCEDURES: SELF-CONTAINED
BREATHING APPARATUS WITH A FULL FACE PIECE OPERATED IN A PRESSURE DEMAND
OR OTHER POSITIVE PRESSURE MODE.
UNUSUAL FIRE AND EXPLOSION HAZARDS: NONE
SECTION V - REACTIVITY DATA
STABILITY: STABLE
CONDITIONS TO AVOID: STRONG OXIDIZING AGENTS, ACIDS
INCOMPATIBILITY (MATERIALS TO AVOID): NONE
HAZARDOUS DECOMPOSITION OR BYPRODUCTS: NONE
HAZARDOUS POLYMERIZATION: WILL NOT OCCUR
SECTION VI - HEALTH HAZARD DATA
INHALATION HEALTH RISKS AND SYMPTOMS OF EXPOSURE:
SKIN AND EYE CONTACT HEALTH RISKS AND SYMPTOMS OF EXPOSURE:
EYE MAY CAUSE EYE IRRITATION.
SKIN PROLONGED OR REPEATED AND CONFINED EXPOSURE
MAY CAUSE SKIN IRRITATION. REPEATED CONTACT MAY CAUSE
DRYING OR FLAKING OF SKIN.
SKIN ABSORPTION HEALTH RISKS AND SYMPTOMS OF EXPOSURE: A SINGLE PROLONGED
EXPOSURE IS NOT LIKELY TO RESULT IN THE MATERIAL BEING ABSORBED THROUGH THE
SKIN IN A HARMFUL AMOUNT. THE DERMAL LD50 HAS NOT BEEN DETERMINED. INGESTION
HEALTH RISKS AND SYMPTOMS OF EXPOSURE: SWALLOWING CAN CAUSE GASTROINTESTINAL
IRRITATION, NAUSEA, AND DIARRHEA.
CARCINOGENICITY: THIS MATERIAL IS NOT CONSIDERED TO BE A CARCINOGEN BY THE
NATIONAL TOXICOLOGY PROGRAM, THE INTERNATIONAL AGENCY FOR RESEARCH ON CANCER,
OR THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
NTP? NO IARC MONOGRAPHS? NO OSHA REGULATED?
NO
10001, 6001
SECTION VI - HEALTH HAZARD DATA - CONT.
EMERGENCY AND FIRST AID PROCEDURES:
EYES IRRIGATE WITH FLOWING WATER IMMEDIATELY AND CONTINUOUSLY FOR
15 MINUTES. CONSULT MEDICAL PERSONNEL.
SKIN WASH OFF IN FLOWING WATER OR SHOWER.
REMOVE CONTAMINATED CLOTHING AND WASH BEFORE REUSE.
INGESTION DO NOT INDUCE VOMITING. RINSE MOUTH WITH WATER, THEN
DRINK ONE GLASS OF WATER. CONTACT A DOCTOR IMMEDIATELY.
INHALATION REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE MOUTH TO MOUTH
RESUSCITATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN.
SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
SMALL SPILL- ABSORB LIQUID ON PAPER, VERMICULITE, FLOOR ABSORBENT OR OTHER
ABSORBENT MATERIAL AND TRANSFER TO LABELED CONTAINERS.
LARGE SPILL- STOP SPILL AT SOURCE, DIKE AREA OF SPILL TO PREVENT SPREADING,
PUMP LIQUID INTO SALVAGE TANK. REMAINING LIQUID MAY BE TAKEN UP ON
SAND , CLAY, FLOOR ABSORBENT OR OTHER ABSORBENT MATERIAL AND SHOVELED INTO
LABELED CONTAINERS.
WASTE DISPOSAL METHOD: REVIEW FEDERAL, PROVINCIAL AND LOCAL GOVERNMENT
REQUIREMENTS PRIOR TO DISPOSAL.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: EXERCISE REASONABLE
CARE AND CAUTION. STORE IN A COOL DRY PLACE.
OTHER PRECAUTIONS: CONTAINERS OF THIS MATERIAL MAY BE HAZARDOUS WHEN
EMPTIED, SINCE EMPTIED CONTAINERS RETAIN PRODUCT RESIDUES (VAPOR, LIQUID AND/OR
SOLIDS), ALL HAZARD PRECAUTIONS GIVEN IN THE DATA SHEET MUST BE OBSERVED.
SECTION VIII - CONTROL MEASURES
RESPIRATORY PROTECTION: IF TVL OF THE PRODUCT OR ANY COMPONENT IS
EXCEEDED, A NIOSH/MSHA JOINTLY APPROVED AIR SUPPLIED RESPIRATOR IS ADVISED
IN ABSENCE OF PROPER ENVIRONMENTAL CONTROL. OSHA REGULATIONS ALSO PERMIT
OTHER NIOSH/MSHA RESPIRATORS UNDER SPECIFIED CONDITION.
VENTILATION: PROVIDE GENERAL OR MECHANICAL VENTILATION OR LOCAL EXHAUST
TO KEEP VAPOR CONCENTRATIONS BELOW TLV OF MATERIALS IN SECTION II AND LEL
IN SECTION IV.
PROTECTIVE GLOVES: USE IMPERMEABLE GLOVES TO PREVENT PROLONGED SKIN
CONTACT.
EYE PROTECTION: USE SAFETY EYEWEAR DESIGNED TO PROTECT EYES AGAINST
LIQUID SPLASH AND MISTS. CONSULT YOUR SAFETY EQUIPMENT SUPPLIER.
OTHER PROTECTIVE CLOTHING OR EQUIPMENT: USE PROTECTIVE CLOTHING TO
PREVENT SKIN CONTACT. USE HEAD CAPS, BOOTS, CHEMICAL APRONS WHEN NECESSARY.
WORK/HYGIENIC PRACTICES: EYEWASHES AND SAFETY SHOWERS IN THE WORKPLACE
ARE RECOMMENDED. WASH HANDS AFTER USING. MONITOR EXPOSURE LEVELS.
SECTION IX – DISCLAIMER
NOTICE: ALTHOUGH THE INFORMATION AND RECOMMENDATIONS SET FORTH HEREIN (HEREINAFTER "INFORMATION") ARE PRESENTED IN GOOD FAITH AND BELIEVED TO BE CORRECT AS OF THE DATE HEREOF, WINSOL LABORATORIES, INC. MAKES NO REPRESENTATIONS AS TO THE COMPLETENESS OR ACCURACY THEREOF. INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING SAME WILL MAKE THEIR OWN DETERMINATION AS TO THE SUITABILITY FOR THEIR PURPOSES PRIOR TO USE. IN NO EVENT WILL WINSOL LABORATORIES, INC. BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR RELIANCE UPON INFORMATION. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.
TLV IS A REGISTERED TRADEMARK OF THE AMERICAN CONFERENCE OF GOVERNMENTAL
INDUSTRIAL HYGIENISTS (ACGIH)
REVISED
01-01-03 – UPDATE VOC LEVEL